How to perform CW simulation. A CW simulation only allows for taking into account the steady-state of the system response. The CW simulation considers that the envelope signal varies slowly over time, with regard to time constants of the system. A CW simulation is much faster than a transient simulation, however it is only possible for CW pulse type excitation, with constant (or slow) amplitude and frequency transition.
How to perform transient simulation. The transient simulation in VISION allows to obtain the time domain response of a non-linear circuit excited by a modulated complex signal.
How to perform a simulation with block sweep of variables, i.e. they vary at the same time. Here we present an example of a transient simulation in which different signal files are used in the AWG-VS block with associated input power.
How to perform a simulation with nested sweep of variables. Here we present an example of a CW simulation in which the power of the input signal and the carrier frequency are varied.
How to perform statistical analysis. Statistical analysis makes it possible to perform a simulation in which variables or models follow a statistical law.
How to perform a model export from System Architect application. The model export make possible to use a model outside from VISION environnment in order to use other kind of analysis tool. The model export is currently interfaced with SystemVue, VSS, Simulink and the Comlib2 module.
How to perform co-simulation with Matlab. VISION allows to set up co-simulation process using Matlab API block.
How to perform 2-tone simulation. 2-tone simulation in VISION allows to obtain time domain response of nonlinear circuit excited by 2-tone complex signal varying in frequency spacing and average power.
This manual describes the procedure for using IQ measurements obtained from IQSTAR software to perform transient simulation. The transient simulator in VISION allows for obtaining the time domain response of a non-linear circuit excited by a modulated complex signal which can then be compared to measurement data from IQSTAR.
How to perform transient simulation using UWF file generated from topics/waveform_generator.html tool. The transient simulation in VISION allows to obtain the time domain response of a non-linear circuit excited by a modulated complex signal.
How to perform a simulation involve parameterized SnP component in System Architect application. The blocks are used to simulate, interpolate and extrapolate discretized SnP data along one or more control data (i.e. parameters)..
How to perform a simulation involve tunable filter in System Architect application. The blocks are used to simulate, interpolate and extrapolate discretized S2P data along one control data in continous mode.
To perform a Load Pull simulation, the "IDEAL TUNER" block(See topics/Ideal_tuner.html#Ideal_tuner) generates a file with a pattern of impedances, which can be added to "ERHO" block at the end of the schematic. The impedance is then swept using the VAR block, which varies the index of the impedance in the file created by the ideal tuner. The load can be defined in either magnitude and phase format or real and imaginary format...