Warning messages during the identification process

STAN Tool will warn the user when the simulated transfer function H0(jωS) presents some of the following characteristics:

SISO method :

  • The variation range of the magnitude of the frequency response is excessive



  • The algorithm cannot achieve the phase tolerance value.



  • Only mathematical poles are detected during the identification process.

DACWIN method :

  • Numerical noise: risk of overmodeling, relax the phase tolerance.

  • In extremely noisy frequency responses, the DACWIN method may try to continue the division in smaller sub-bands to infinity. The warning message is: “Maximum phase tolerance used. Your original curves might be too noisy to be identified. Please use manual order to avoid any identification problem.

SISO/DACWIN method:

  • Phase tolerance value at the end of the identification when using the advanced option Sensitivity Policy ==> Release Tolerance Once