MULTI CW BUS
Description : this is a block that allows to simulate a CW RF voltage or current source for driven antenna simulation. This source is mainly used in CW(Continuous Wave) simulation mode, see Simcontroller.
- Signal Type : allows to configure the output signal as complex or real.
- Signal amplitude units :
dBm or volts. If dBm the reference impedance "Resistance" is used within the following equation:
.
- Resistance: internal impedance of the sources.
- Phase : phase of tone in degree.
- Amplitude : amplitude of tone in 'signal amplitude unit'.
- Number of ports : This represents the number of output ports in the bus, as well as the number of parallel sources represented by the block.
- Add noise : validate in order to take into account the noise.
- Use noise file : user can add one NF file to describe the additionnal noise.

Tag as model export : check it in order to use the connected node as an input port. See Perform model export.