AM3111 Bipolar SMU +/-25V +/-200mA
The AM3111 SMU is embedded into the AM3100 controller chassis, as a bipolar pulse voltage and current generator.
PURPOSE | GATE |
OPERATING RANGE | |
Switched voltage levels | 2 |
Voltage | ±25V |
Pulsed current | ±0.2A |
Source DC | 3W Max |
Sink DC | 0.5W Max |
SOURCE PERFORMANCE | |
Voltage setting resolution | 16bit 1mV |
Output impedance | ON: 50Ω / OFF: 50mΩ |
PULSE TIMING | |
Pulse Timing | Pulse width from 1.1µs to 10s /20ns (Within Power limits) |
PRF | From 0.1Hz to 200kHz |
MEASUREMENT PERFORMANCE | |
V range | 25V |
I range | 5mA/200mA |
V & I Meas. Accuracy | 7.5mV+0.1% ; 10µA+0.2% / 100µA+0.2% |
Settling time | 2-4µs |
Output connector | BNC |
AM3111 Bipolar SMU +/-25V +/-200mA
The AM3111 SMU is embedded into the AM3100 controller chassis, as a bipolar pulse voltage and current generator.
PURPOSE | DRAIN |
OPERATING RANGE | |
Switched voltage levels | From 0V |
Voltage | up to +120V |
Pulsed current | +30A |
Average & RMS Current | 5A & 10A |
DC power / Pulse Power | 220W / 3KW |
SOURCE PERFORMANCE | |
Output impedance | 0,1Ω |
PULSE TIMING | |
Pulse timing | Pulse width from 1.1µs to 10s / 20ns (Within Power limits) |
PRF | 0.1Hz to 100kHz |
MEASUREMENT PERFORMANCE | |
V range | 125V |
I range | 33A |
V & I ADC resolution | 16bit |
Absolute Accuracy | 20mV +0.1% ; 20mA + 0.3% |
Settling time | 500ns to 95%, 2µs to ADC resolution |
Output connector | BNC |
AM3121 Probe +120V +30A
The AM3121 probe is compatible with the AM3100 controller and is dedicated to bias transistor drain for general purpose measurements.
PURPOSE | GATE |
OPERATING RANGE | |
Switched voltage levels | 2 |
Voltage | ±25V |
Pulsed current | ±0.2A |
Source DC | 3W Max |
Sink DC | 0.5W Max |
SOURCE PERFORMANCE | |
Voltage setting resolution | 16bit 1mV |
Output impedance | ON: 50Ω / OFF: 50mΩ |
PULSE TIMING | |
Pulse Timing | Pulse width from 1.1µs to 10s /20ns (Within Power limits) |
PRF | From 0.1Hz to 200kHz |
MEASUREMENT PERFORMANCE | |
V range | 25V |
I range | 5mA/200mA |
V & I Meas. Accuracy | 7.5mV+0.1% ; 10µA+0.2% / 100µA+0.2% |
Settling time | 2-4µs |
Output connector | BNC |
AM3111 Bipolar SMU +/-25V +/-200mA
The AM3111 SMU is embedded into the AM3100 controller chassis, as a bipolar pulse voltage and current generator.
PURPOSE | DRAIN |
OPERATING RANGE | |
Switched voltage levels | From 0V |
Voltage | up to +120V |
Pulsed current | +30A |
Average & RMS Current | 5A & 10A |
DC power / Pulse Power | 220W / 3KW |
SOURCE PERFORMANCE | |
Output impedance | 0,1Ω |
PULSE TIMING | |
Pulse timing | Pulse width from 1.1µs to 10s / 20ns (Within Power limits) |
PRF | 0.1Hz to 100kHz |
MEASUREMENT PERFORMANCE | |
V range | 125V |
I range | 33A |
V & I ADC resolution | 16bit |
Absolute Accuracy | 20mV +0.1% ; 20mA + 0.3% |
Settling time | 500ns to 95%, 2µs to ADC resolution |
Output connector | BNC |
AM3121 Probe +120V +30A
The AM3121 probe is compatible with the AM3100 controller and is dedicated to bias transistor drain for general purpose measurements.